For estimators, builders and building designers. One-page PDF per series with performance figures, construction, glazing options and section drawing. Data for all 46 series is also in a CSV file.

In supply now: the 70 series thermally broken casement; the other series are on request for projects. 28 of the 46 series are thermally broken. The lowest whole-window U-value is Uw 1.2 W/m²K (120 Narrow-Frame Thermally Broken Casement, 120 Motorised Horizontal Sliding Window, 120 Oversize Motorised Tilt Window, 120 Casement with Integrated Inner Sash); the quietest is the 93 High-Performance Energy Casement at Rw+C 45–50 dB; the highest water tightness is 800 Pa (93 High-Performance Energy Casement). All figures are the factory's published test results.

SeriesFrameThermal breakUw W/m²KRw+C dBWater PaWind kPaPDF
Windows
120 Narrow-Sash Casement Window120 mmYes1.540–457005.0PDF
120 Narrow-Frame Thermally Broken Casement120 mmYes1.240–456005.0PDF
120 Motorised Horizontal Sliding Window120 mmYes1.240–456005.0PDF
120 Oversize Motorised Tilt Window120 mmYes1.240–456005.0PDF
120 Casement with Integrated Inner Sash120 mmYes1.240–457005.0PDF
115 Tilt & Turn Window115 mmYes1.440–456005.0PDF
108 Casement with Micro-Ventilation108 mmYes1.440–457005.0PDF
116 Thermally Broken Casement Window116 mmYes1.835–406005.0PDF
100P Thermally Broken Casement Window100 mmYes1.835–406005.0PDF
100 Awning Window with Folding Flyscreen100 mmNo2.225–355004.0PDF
93 Thermally Broken Casement Window93 mmYes1.540–457005.0PDF
93 High-Performance Energy Casement93 mmYes–45–508006.0PDF
70 Outward-Opening Casement Window70 mmYes1.835–407005.0PDF
70 Thermally Broken Casement Window70 mmYes1.835–407005.0PDF
60 Thermally Broken Casement Window60 mmYes1.830–357005.0PDF
45 Casement Window (Non-Thermal)45 mmNo2.125–306004.0PDF
Extra-Large Fixed Window–Yes2.125–306004.0PDF
105 Thermally Broken Double Hung Window125 mmYes1.540–457005.0PDF
116 Aluminium Louvre Window116 mmYes––––PDF
100-66 Three-Track Sliding Window100 mmNo2.225–306004.0PDF
100 Three-Track Sliding Window100 mmNo2.225–306004.0PDF
120-30 Slim Thermally Broken Sliding Window120 mmYes1.630–357005.0PDF
Doors
18 mm Ultra-Slim Three-Track Sliding Door110 mmNo1.825–306004.0PDF
110-82 Heavy-Duty Sliding Door110 mmNo1.825–306004.0PDF
120 Thermally Broken Heavy-Duty Sliding Door120 mmYes1.630–356005.0PDF
80 Thermally Broken Heavy-Duty Sliding Door139 mmYes1.635–407005.0PDF
100 Thermally Broken Heavy-Duty Sliding Door139 mmYes1.540–458005.0PDF
139 Lift & Slide Door139 mmYes1.440–458005.0PDF
75 Thermally Broken Bifold Door75 mmYes1.440–457005.0PDF
Sensor-Activated Electric Sliding Door110 mmNo1.825–306004.0PDF
45 Hinged Door45 mmNo2.225–306004.0PDF
60 Thermally Broken Hinged Door60 mmYes1.830–356004.0PDF
120 Hinged Door with Integrated Flyscreen120 mmYes1.735–407005.0PDF
100 Aluminium Panel Entrance Door100 mmYes1.540–457005.0PDF
100 Thermally Broken Entrance Door100 mmYes1.540–457005.0PDF
70 Commercial Hinged Door70 mmYes1.630–357005.0PDF
108 Floor-Spring Double Door108 mmNo1.825–256004.0PDF
Shopfront Door System100 mmNo1.835–407005.0PDF
Skylights & sunrooms
Curtain Wall Glazing––––––PDF
Glass Balustrade––––––PDF
Opening Overhead Skylight––––––PDF
Sliding Skylight––––––PDF
Electric Folding Roof Window––––––PDF
Flat-Roof Sunroom–––––5.0PDF
Pitched-Roof Sunroom–––––5.0PDF
Gable-Roof Sunroom–––––5.0PDF

Reading the figures

Which aluminium window series has the lowest U-value?

In this range the 120 Narrow-Frame Thermally Broken Casement, the 120 Motorised Horizontal Sliding Window, the 120 Oversize Motorised Tilt Window, the 120 Casement with Integrated Inner Sash share the lowest factory Uw, 1.2 W/m²K. Standard non-thermal frames test at about 2.1–2.2 W/m²K.

What does Uw mean on a window spec sheet?

Uw is the heat-transfer coefficient of the whole window (frame plus glass), in W/m²K. Lower means less heat lost or gained. Energy assessors also use the SHGC (solar heat gain coefficient) of the glass; we supply both per series for NatHERS, BASIX or NCC reports.

How do water tightness and wind load figures relate to AS 2047?

AS 2047 tests windows to a performance rating set by the site’s wind classification under AS 4055: the higher the class, the higher the test pressures for wind, water and air. Compare the series figures with your site class and confirm with the AS 2047 test report we send with the quote.

Can I get CAD or DWG section drawings?

Section drawings are shown on each spec sheet. DWG files for a series are available on request for architects, building designers and estimators: ask through the enquiry form with the series name.

Is the data available in a spreadsheet?

Yes. Download the CSV of all 46 series with frame depth, thermal break, Uw, Rw+C, water tightness and wind load.

Need DWG drawings or test reports?

Tell us the series and the project. We send section drawings, the AS 2047 test report and energy data.

We reply within 2 business days with landed project pricing. Your details only go to us.